Kleenpak™ sterile connectors

Gendered dry connection of two separate fluid pathways

The disposable Kleenpak™ sterile connector, a Pall Life Sciences products, allows for the dry connection of two separate fluid pathways, while maintaining the sterile integrity of both. The connector consists of a male and a female connector, each covered by a vented peel-away strip that protects the port and maintains the sterility of the sterile fluid pathway.

The connector consists of a male and a female connector, each covered by a vented peel-away strip that protects the port and maintains the sterility of the sterile fluid pathway. Different connector options are available to allow for the connection of 15.8 mm (⅝ in.), 13 mm (½ in.), 9.6 mm (⅜ in.) or 6 mm (¼ in.) nominal tubing. Kleenpak sterile connectors can either be autoclaved up to 130°C or Gamma sterilized.

Benefits

No capital equipment required
Connection is made in seconds
Connector can be autoclaved or Gamma sterilized
Easy to make connection – even in cramped environment
Maintains a sterile fluid pathway upon activation of device
Peel-away strip maintains sterility until ready to use
Vented to allow steam penetration and to prevent tubing collapse after autoclaving
Shape coding ensures proper alignment
Locking mechanism prevents incorrect assembly
Device makes audible click when engaged
Permanent connection for security – cannot be re-opened 

Quality Standards

Manufactured under clean conditions in a controlled environment
Manufactured under a Quality Management System certified to ISO 9001
Supplied with a Certificate of Test confirming the quality standards and quality control tests performed by Pall (including endotoxin USP<85> and particulate tests)

Validation tests include:

Burst
Creep-rupture
Tensile strength
Aerosol challenge
Shelf-life
Absence of BPA (Bisphenol-A)
Bacterial spore challenge (‘soiling’) test
Closure integrity
Water flow characteristics
Extractables
Autoclave

The fluid path materials of construction meet:
Biological Reactivity Tests in vivo for Class VI-121°C Plastics, USP <88>
USP Physicochemical Tests for plastics, USP<661>

Connector Validation

Pall offers a comprehensive connector validation service to ensure a smooth product implementation without delay. Validation packages will be tailored to meet your specific needs and will include some or all of the following:

Compatibility assessment
Extractables analysis
Soiling test

Applications

Transfer of inoculums to reactors
Sampling during fermentation or cell culture
Connection of small sterile equipment to large equipment (e.g., bioreactors)
Handling of bulk material in a nonsterile environment
Connection from tank to filling line
Connection to a disposable system
Sensor insertion into bioreactor
Connectors and Disconnectors

【智荟直播间】一触即合:生物分子间的亲和之约

立即学习

【智荟直播间】一触即合:生物分子间的亲和之约

观看学习

【智荟直播间】一触即合:抗体亲和层析十八般武艺

立即学习

【智荟直播间】一触即合:抗体亲和层析十八般武艺

观看学习

【智荟直播间】一触即合:His标签亲和层析的纯化之道

立即学习

【智荟直播间】一触即合:His标签亲和层析的纯化之道

观看学习

【智荟直播间】分子迷宫:凝胶层析的筛选之旅

立即学习

【智荟直播间】分子迷宫:凝胶层析的筛选之旅

观看学习

第1页 共4个课程

搜索未找到相关记录,请换个查询条件尝试。