HiScreen™ Capto™ Octyl HIC column

Prepacked with Capto™ Octyl hydrophobic interaction chromatography (HIC) resin for use in method and process development workflows

HiScreen™ Capto™ Octyl
Chromatography technique Hydrophobic interaction chromatography
Chromatography resin Capto™ Octyl
Bed dimensions 7.7 × 100 mm
Bed height 100 mm
Bed volume 4.7 mL
Column i.d. 7.7 mm
Flow velocity ≤ 600 cm/h
Pressure max. (over the packed bed during operation) 3 bar [0.3 MPa] (44 psi)
Recommended Flow Rate 2.7 mL/min
Storage 4 to 30°C, 20% Ethanol
SKU: 17546510 分类: , ,

This column packed with Capto™ Octyl resin is designed for HIC process development.

  • Prepacked with Capto™ Octyl high-flow and high-capacity HIC resin for capture and intermediate purification processes
  • Designed for efficient process development: convenient method optimization and parameter screening are enabled by the 10 cm bed height
  • Small bed volume for fast results and minimal sample/buffer consumption
  • Delivers reproducible results, and scalable

About HiScreen™ column format for process development

HiScreen™ columns are part of the process development platform available from Cytiva. The columns are designed for method optimization and parameter screening. HiScreen™ columns have small bed volumes (4.7 mL), reducing the cost of sample and buffer consumption.

Method optimization and parameter screening

When developing a new process, parameters such as selectivity, capacity, and binding and elution conditions must be screened at smaller scale to save time and money. We suggest starting with high‑throughput parallel screening of process conditions which is easily performed using 96‑well PreDictor™ plates prefilled with BioProcess™ resin. During the process development, HiScreen™ prepacked column format is available for further method optimization, or for the fine-tuning and verification of parameters.

Scale-up

Scale‑up of a chromatography step can be as straightforward as increasing column diameter to accommodate a larger feed volume while keeping the bed height and the linear flow velocity constant. The 10 cm bed height of HiScreen™ columns gives sufficient residence time to serve as the basis for linear process scale‑up. However, when needed, two columns can easily be connected in series to increase the bed height.

Capto™ Octyl – a high-flow and high-capacity HIC resin

Capto™ Octyl hydrophobic interaction chromatography resin has an octyl ligand for the capture and intermediate purification of monoclonal antibodies (mAbs), mAb variants, and other biomolecules. It combines high capacity, narrow specification range, high flow rate, and low backpressure to meet the demands of large-scale biopharmaceutical manufacturing.

Not sure which HIC resin you should use? We recommend starting with one of the kits below:

Capto™ Octyl is available in other formats (Figure 1):

These formats support various scales of work from process development screening to GMP manufacturing.

Fig 1. Prepacked chromatography formats available from Cytiva to support various scales, from screening to GMP manufacturing.